Electric furnace transfer

Overview

This series of products adopt high-quality silicon steel sheets according to strictly regulated operating technology. Lamination of iron cores adopts 450 three-level whole inclined joint, imperforate colligation, screw rod connection and draw plate clamping structure. The surface is coated with No.7110 paint and coils adopt high-quality oxygen-free copper low color line and high-quality wires including Dupont materials. New-type structure is adopted for the winding of high and low voltage coils, so as to increase anti-short-circuit and shock resistance ability of the product. The product is widely applied to the fields of nonferrous and ferrous metal smelting as well as non-metal smelting.

  • Execution standard
  • Model
  • Performance
  • Parameters
  • Appearance
    • GB1094.11-2007 Power transformer
    • J13/T 8636-1997 Power transformer
  • Null
  • Transformer of loaded voltage regulation calcium carbide furnace
    Type volume (kVA) Primary voltage
    (kV)
    Secondary voltage
    (V)
    Conn. Symb. Cooling way Standard Enterprise standard
    No-load loss
    (kW)
    On-load loss
    (kW)
    No-load loss
    (%)
    Short circuit
    (%)
    No-load loss
    (kW)
    No-load loss
    (kW)
    No-load loss
    (%)
    HCSSPZ-10000 3.5 38.5 155-100 Y.D11/D.d Strong oil water cooled 17140 5 6-8 13.6981.1
    HCSSPZ-12500160-1001816214.4113.4
    HCSSPZ-16000170-10523.619618.9137.2
    HCSSPZ-20000180-11026240 1.5 20.81680.9
    HCSSPZ-25000190-1103029024203
    HCSSPZ-31500205-12535.234028.2238
    Remark:Level XIX loaded voltage regulation (the first five levels are output at a constant rate; the last fourteen levels are output at a constant current).
    Transformer of calcium carbide furnace
    Type volume (kVA) Primary voltage
    (kV)
    Secondary voltage
    (V)
    Conn. Symb. Cooling way Standard Enterprise standard
    No-load loss
    (kW)
    On-load loss
    (kW)
    No-load loss
    (%)
    Short circuit
    (%)
    No-load loss
    (kW)
    No-load loss
    (kW)
    No-load loss
    (%)
    HCS-1000 6
    6.3
    10
    10.5
    35
    57-73 D.do-12 Voltage regulation mode 3.2721.43 6-8 2.62171.5
    HCS-12504.0826.733.321.31.5
    HCS-1600 67-834.428.833.5231.5
    HCS-18004.9532.43424.31.5
    HCS-2000 72-96 5.53634.4271.3
    HCS-25006.8510.63t5.530.51.3
    HCSSP-3150 90-110D.do-12 Voltage regulation mode 7.851.236.335.91.2
    HCSSP-36008.9t58.537.15411.2
    HCSSP-40009.16537.3461.2
    HCSSP-5000 3.5
    38.5
    90-110 D.do-12 Voltage regulation mode 10.2702.5 6-8 8.2491.2
    HCSSP-6300 108-128 11.5902.59.45631.2
    HCSSP-800013.21122.510.678.51.2
    HCSSP-10000 100-140 D.do-12
    D.do-11
    16.6130213.2911.2
    HCSSP-1250017.5154214107.81.1
    HCSSPZ-16000105-17021.6190217.31331.1
    HCSSPZ-20000110-18024245219.2171.50.9
    HCSSPZ-25000115-1952827022.41890.9
    HCSSPZ-31500125-2053232525.6227.50.9
    Remark:5000-8000kVA belong to non-excitation electric voltage regulation; above 10000kVA belongs to loaded voltage regulation .
    Transformer of yellow phosphorus furnace
    Model volume Rated voltage Standard Enterprise standard
    High voltage (kV) Low voltage (V) No-load loss
    (kW)
    On-load loss
    (kW)
    No-load loss
    (%)
    Short circuit
    (%)
    No-load loss
    (kW)
    On-load loss
    (kW)
    No-load loss
    (%)
    HLS-2000 6
    6.3
    10
    35
    180,167.5,155,142.5,1304.82937-83.8420.31.5
    HLS-2500215,200,185,168,1305.73437-84.5623.81.5
    HLSSP-3150230,215,200,180,1306.84137-85.4428.71.5
    HLSSP-4000245,231,218,206,196,178,1408.2/9.451/582.87-86.56/7.5235.7/40.61.4
    HLSSP-5000260,245,232,220,199,182,1409.8/11.559/682.66-87.84/9.241.3/47.61.3
    HLSSP-6300270,252,236,220,207,185,14012/13.570/802.46-89.6/10.849/561.2
    HLSSP-8000300,274,255,237,222,196,14014.5/1684/952.26-811.6/12.858.8/66.51.1
    HLSSPZ-6300 35 270-1401710026-813.6701
    HLSSPZ-8000302-1401915126-815.280.51
    HLSSPZ-10000320-1402213526-817.694.51
    HLSSPZ-12500338-1402515326-720107.01
    HLSSPZ-16000374-1403018226-724127.41
    HLSSPZ-20000401-140342151.86-727.2150.51
    HLSSPZ-25000428-140402521.66-732176.40.9
    HLSSPZ-31500456-140483001.46-738.42100.9
    Remark:6300kVA-12500kVA belongs to Level XIX voltage regulation; the first five levels are output at a constant power; the last fourteen levels are output at a constant current.
    Transformer of electrical slag furnace
    Model (kVA) Primary voltage (V) Scope of secondary voltage (V) Voltage regulation mode Voltage regulation level Volume of attached saturated reactor (kvar) Impedance (%)
    HZ-200 6
    6.3
    10
    35
    30-60 Non-excitation voltage regulation 5-7 10kV 时5-7
    35kV 时6-8
    HZ-63035-70
    HZ-80040-80
    HZ-125045-90 On-load voltage regulation (on-load separate switch is adopted) 19-271330
    HZ-160045-901720
    HZ-200050-1002130
    HZ-250055-1102690
    HZ-315060-1203290
    HZ-800070-140
  • Null